iCoat-200 Coating Thickness Gauge
Scan QR

iCoat-200 Coating Thickness Gauge(1)
iCoat-200 Coating Thickness Gauge(2)
iCoat-200 Coating Thickness Gauge(3)
iCoat-200 Coating Thickness Gauge(4)
iCoat-200 Coating Thickness Gauge(5)
Thumbnail 1
Thumbnail 2
Thumbnail 3
Thumbnail 4
Thumbnail 5

Product Features & Applications

Product Features:

  • Both magnetic and eddy current thickness measurement methods, it can measure the thickness of non-magnetic coatings on magnetic metal substrates and non-conduc- tive coatings on non-magnetic metal substrates.
  • Two Meauring Methods:Continuous and single measure- ment methods
  • Three measuring modes:The high-precision measuring mode can take the average of multiple measurements and automatically filter suspicious data to ensure more accurate and stable measurement values; The fast mea- surement mode can achieve real-time scanning function;
  • Equipped with temperature compensation function: The leading real-time temperature compensation technology can automatically compensate for measurement errors caused by changes in ambient temperature and probe temperature, making measurements more accurate;
  • Five statistical values: Mean(MEAN), Maximum(MAX) , Minimum (MIN), Number of Tests (NO.), and Standard Deviation (S.DEV) ;
  • Zero point calibration, single point calibration, or two-point calibration methods can be used to calibrate the instrument, and basic calibration and temperature coefficient calibration methods can be used to correct the systematic errors of the measuring probe.

Product Applications

  • Used for precise measurement of coating and plating thickness on the surface of metal components;
  • It can detect the coating thickness on the surface of chemical equipment

     

Technical Specifications

Probe TypeFN
Measuring Range0~1500μm0~1500μm Copper plated grid 0~40m
Working PrincipleMagneticEddy
Resolution0.1μm(0~99μm), 1μm(>99μm)
AccuracyZero-point Calibration±(3%H+1)μm±(3%H+1.5)μm
Two-point Calibration±[(1~3)%H+1]μm±[(1~3)%H+1.5]μm
TestConditionsMinimum radius of curvatureConvex 3mm
Minimum area diameterΦ7mm
Matrix critical thickness0.5mm0.3mm
Using EnvironmentTemperature: 0 ℃~40 ℃Humidity: 20% Rh~90% RhNo Strong Magnetic Field Environment
Power2*AA Alkaline batteries
WeightAbout 240g
Dimensions151×76×38mm

Standard Configuration

ItemQty
Main Unit1unit
Iron Substrate1pc
Aluminum Substrate1pc
Calibration Block5pcs
Documents1set
No.5 Alkaline battery (1.5V)1set
Instrument Case1case
×
WeChat QR

Wechat: 13918745376